Hitachi L300P User Manual

Page 108

Advertising
background image

L300P Inverter

Configur

ing Dr

iv

e

P

a

ra

met

e

rs

3–39

“B” Function

Run

Mode

Edit

Lo Hi

Defaults

Units

SRW Display

Func.

Code

Name

Description

–FE2

(CE)

–FU2

(UL)

–FR

(Jpn)

B080

[AM] terminal analog
meter adjustment

Adjust 8-bit gain to analog
meter connected to terminal
[AM], range is 0 to 255

✔ ✔ 180

180

180

>b080 AM-MONITOR

ADJUST 180

B081

[FM] terminal analog
meter adjustment

Adjust 8-bit gain to analog
meter connected to terminal
[FM], range is 0 to 255

✔ ✔

60

60

60

>b081 FM-MONITOR

ADJUST 060

B082

Start frequency adjust-
ment

Sets the starting frequency
for the inverter output, range
is 0.10 to 9.99 Hz

✘ ✔ 0.50 0.50 0.50

Hz

>b082 fmin

F 00.50Hz

B083

Carrier frequency
setting

Sets the PWM carrier (inter-
nal switching frequency).
Range is 0.5 to 8.0 kHz for
–015xxx to –750xxx models
and 0.5 to 12.0 kHz for
–900Hxx to 1320Hxx

✘ ✔

3.0

3.0

3.0

kHz

>b083 CARRIER

F 05.0kHz

B084

Initialization mode
(parameters or trip
history)

Select the type of initializa-
tion to occur, two option
codes:
00 Trip history clear
01 Parameter initialization
02 Trip history clear and

parameter initialization

✘ ✘

00

00

00

>b084 INITIAL

MODE TRP

B085

Country code for initial-
ization

Select default parameter
values for country on initial-
ization, four option codes:
00 Japan version
01 Europe version
02 US version
03 reserved (do not set)

✘ ✘

01

02

00

>b085 INITIAL

SELECT USA

B86

Frequency scaling
conversion factor

Specify a constant to scale
D007 to display in engineer-
ing units.
Range is 0.1 to 99.9

✔ ✔

1.0

1.0

1.0

>b086 F-CONV

Gain 001.0

B087

STOP key enable

Select whether the STOP
key on the keypad is enabled
(req. A002=01, 03, 04, or
05). Two option codes:
00 Enable
01 Disable

✘ ✔

00

00

00

>b087 STOP-SW

SELECT ON

Advertising