Note 1: To ensure safe inverter operation in networked applications, you cannot change an

intelligent terminal assignment to/from [ROK] (option code 49) via the network.
However, you can still read an [ROK] input assignment over the network.

28

DWN

Remote Control
DOWN Function
(motorized speed pot.)

ON

Decelerates (decreases output frequency) motor from
current frequency

OFF

No change to output frequency

29

UDC

Remote Control Data
Clearing

ON

Clears the UP/DWN frequency memory by forcing it
to equal the set frequency parameter F001. Setting
C101 must be set=00 to enable this function to work.

OFF

UP/DWN frequency memory is not changed

31

OPE

Operator Control

ON

Forces the source of the output frequency setting
(A001) and the source of the RUN command (A002)
to be from the digital operator

OFF

Source of output frequency set by (A001) and source
of run command set by (A002) is used

32

SF1

Multispeed bit 1

ON

Logical 1

OFF

Logical 0

33

SF2

Multispeed bit 2

ON

Logical 1

OFF

Logical 0

34

SF3

Multispeed bit 3

ON

Logical 1

OFF

Logical 0

35

SF4

Multispeed bit 4

ON

Logical 1

OFF

Logical 0

36

SF5

Multispeed bit 5

ON

Logical 1

OFF

Logical 0

37

SF6

Multispeed bit 6

ON

Logical 1

OFF

Logical 0

38

SF7

Multispeed bit 7

ON

Logical 1

OFF

Logical 0

39

OLR

Overload restriction

ON

Selects current overload parameter set 2
(B024, B025, B026)

OFF

Selects current overload parameter set 1
(B021, B022, B023)

49

ROK

*1

Run Enable for FW/RV
(–xFU2 and –xFE2
models only)

ON

[FW] and [RV] inputs and operator Run key press
operate normally

OFF

[FW] and [RV] inputs and operator Run key press are
ignored; inverter output remains OFF

no

Not selected

ON

(input ignored)

OFF

(input ignored)

Input Function Summary Table