Programming error codes, Programming error codes 3–60 – Hitachi L300P User Manual

Page 129

Advertising
background image

Programming Error Codes

Configur

ing Dr

iv

e

P

a

ra

meters

3–60

Programming Error Codes

The L300P inverter operator keypad displays a special code (begins with the character) to
indicate a programming error. Programming errors exist when one parameter conflicts with the
meaningful range permitted by related parameter(s). Note that particular real-time frequency
(speed) input levels can cause a conflict in some situations. After a conflict exists, the error
code will appear on the display, or you can view it later with D090 in Monitor Mode. Also, the
PGM LED on the display will flash ON/OFF when programming. These indications are
automatically cleared when the parameter is corrected to the allowed range.

Programming Error

Code

Parameter out of bounds

Boundary defined by...

Code

Description

<, >

Code

Description

001 201

A061 / A261

Frequency upper limit
setting; 1st, 2nd motor

>

A004 /

A204

Maximum frequency;
1st, 2nd motor

002 202

A062 / A262

Frequency lower limit
setting; 1st, 2nd motor

>

004 204

A003 / A203

Base frequency setting;
1st, 2nd motor

>

005 205

F001,
A020 / A220

Output frequency setting,
Multi-speed freq. setting;
1st, 2nd motor

>

006 206

A021 to A035 Multi-speed freq. settings

>

012 212

A062 / A262

Frequency lower limit
setting; 1st, 2nd motor

>

A061 / A261

Frequency upper limit setting;
1st, 2nd motor

015 215

F001,
A020 / A220

Output frequency setting,
Multi-speed freq. setting;
1st, 2nd motor

>

016 216

A021 to A035 Multi-speed freq. settings

>

021 221

A061 / A261

Frequency upper limit
setting; 1st, 2nd motor

<

A062 / A262

Frequency lower limit setting;
1st, 2nd motor

025 225

F001,
A020 / A220

Output frequency setting,
Multi-speed freq. setting;
1st, 2nd motor

<

031 231

A061 / A261

Frequency upper limit
setting; 1st, 2nd motor

<

B082

Start frequency adjustment

032 232

A062 / A262

Frequency lower limit
setting; 1st, 2nd motor

<

035 235

F001,
A020 / A220

Output frequency setting,
Multi-speed freq. setting;
1st, 2nd motor

<

036

A021 to A035 Multi-speed freq. settings

<

037

A038

Jog frequency setting

<

085 285

F001,
A020 / A220

Output frequency setting,
Multi-speed freq. setting;
1st, 2nd motor

>f-x,
<f+x

A063 ± A064
A065 ± A066
A067 ± A068

Jump (center) frequency ±
jump (hysteresis) frequency
width setting

(See note after table)

086

A021 to A035 Multi-speed freq. settings

>f-x,
<f+x

Advertising