Using Intelligent Input Terminals

Oper

ations

a

nd Moni

tor

ing

4–14

The Bit Operation method of speed control uses up to five intelligent inputs to select any of up
to six speeds from a total of eight speeds. (At least two of the SF1–SF7 functions will be
unused, since there are only five inputs.) Since the all-switches-OFF combination selects the
first speed, you only need N-1 switches to select N speeds. With Bit Operation speed control,
only one input is normally active at a time. If multiple switches are ON, the lower numbered
input takes precedence (determines the speed). The table and figure below show how the input
combinations work.

The following table lists the option codes for assigning [SF1 to [SF7] to the intelligent inputs.

0th

SF1

SF2

SF3

3rd

4th

2nd

5th

1st

Speed

Switches

Fwd Run

SF4

SF5

Note: Input functions SF6 and SF7 may be substituted
for any of SF1–SF5, to access Speed 7 or Speed 8.

Multi-

speed

Input Function

SF7

SF6

SF5

SF4

SF3

SF2

SF1

Speed 0

0

0

0

0

0

0

0

Speed 1

1

Speed 2

1

0

Speed 3

1

0

0

Speed 4

1

0

0

0

Speed 5

1

0

0

0

0

Speed 6

1

0

0

0

0

0

Speed 7

1

0

0

0

0

0

0

Opt.

Code

Symbol

Function Name

Description

32

SF1

Bit-level speed select 1

Bit-level speed select, Bit 0

33

SF2

Bit-level speed select 2

Bit-level speed select, Bit 1

34

SF3

Bit-level speed select 3

Bit-level speed select, Bit 2

35

SF4

Bit-level speed select 4

Bit-level speed select, Bit 3

36

SF5

Bit-level speed select 5

Bit-level speed select, Bit 4

37

SF6

Bit-level speed select 6

Bit-level speed select, Bit 5

38

SF7

Bit-level speed select 7

Bit-level speed select, Bit 6

Valid for
inputs:

C001, C002, C003, C004,
C005

Required
settings:

F001, A020 to A035
A019=00

Notes:
When all [SFx] inputs are OFF, the speed is

set by default to the value in F001.

When a multi-speed setting more than

50Hz(60Hz) is to be set, it is necessary to
program the maximum frequency A004 high
enough to allow that speed.

5

3

1

4

2

FW

TH

PLC

P24

CM1

SF2

SF1

SF4

SF3

SF5

Example (requires input configuration—
see page

3–43

):

See I/O specs