Spare parts, Capacitor life curve – Hitachi L300P User Manual

Page 214

Advertising
background image

Maintenance and Inspection

T

roub

leshooting

and Maintenance

6–12

Spare parts

We recommend that you stock spare parts to reduce down time, including parts listed below:

Capacitor
Life Curve

The DC bus inside the inverter uses a large capacitor as shown in the diagram below. The
capacitor handles high voltage and current as it smooths the power for use by the inverter. So,
any degradation of the capacitor will affect the performance of the inverter. The capacitor bank
in L300P series inverters is replaceable. This section will show you how to replace it in the
field.

Capacitor life is reduced in higher ambient temperatures, as the graph below demonstrates. Be
sure to keep the ambient temperature at acceptable levels, and perform maintenance inspections
on the fan, heat sink, and other components. If the inverter is installed on a cabinet, the ambient
temperature is the temperature inside the cabinet.

Part description

Symbol

Quantity

Notes

Used

Spare

Cooling fan

FAN

1, 2, 3... (depends

on model)

1 or 2

Fan unit at top of housing
in all models

Auxiliary cooling fan

FAN

0 or 1... (depends

on model)

0 or 1

–185Lxx, –220Lxx, and
–300Lxx models

Capacitor bank

CB

1

1

All models

Power

Input

Inverter

L1

Motor

L2

L3

Rectifier

Variable-frequency Drive

Internal DC Bus

+

+

U/T1

V/T2

W/T3

Converter

1

2

3

4

5

6

7

8

9

10

0

20

30

40

50

Ambient

temperature, °C

Years

Capacitor Life Curve

12 hrs / day operation

24 hrs / day operation

Advertising