Choosing a braking unit – Hitachi L300P User Manual

Page 198

Advertising
background image

Dynamic Braking

Motor Contro

l

Ac

cess

or

ies

5–8

Choosing a
Braking Unit

The L300P Series 200V and 400V class inverter models in the 25 to 175 hp range require
external braking units to increase their braking torque. Braking units come in sizes correspond-
ing to the power handing requirements for particular resistor selections. Be sure to follow the
installation instructions accompanying each braking unit. The following table lists the L300P
inverter models and their applicable braking units.

25 to 175 hp (18.5 to 132 kW)

Peformance Versus External Braking Unit

Without
Braking

Unit

With Braking Unit

Voltage

Class

Model Number

L300P

Motor

hp

Braking

Torque,

%

Braking Unit

Model

Minimum

Resistance,

Ohms

Max.

Braking

Duty Cycle,

%

Minimum

Resistance

@ 100%

Braking

Duty Cycle,

Ohms

200V

–185LFU2

25

10

BRD–E2

17

10

46

10

BRD–E2–30K

4

20

6

–220LFU2

30

10

BRD–E2

17

10

46

10

BRD–E2–30K

4

20

6

–300LFU2

40

10

BRD–E2–30K

4

20

6

10

BRD–E2–55K

2

20

4

–370LFU2

50

10

BRD–E2–55K

2

20

4

–450LFU2

60

10

BRD–E2–55K

2

20

4

–550LFU2

75

10

BRD–E2–55K

2

20

4

–750LFU2

100

10

BRD–E2–55K

2

20

4

400V

–185HFU2, HFE2

25

10

BRD–EZ2

20

10

34

10

BRD–E2–30K

10

10

24

–220HFU2, HFE2

30

10

BRD–EZ2

20

10

34

10

BRD–E2–30K

10

10

24

–300HFU2, HFE2

40

10

BRD–EZ2–55K

6

20

12

–370HFU2, HFE2

50

10

BRD–EZ2–55K

6

20

12

–450HFU2, HFE2

60

10

BRD–EZ2–55K

6

20

12

–550HFU2, HFE2

75

10

BRD–EZ2–55K

6

20

12

–750HFU2, HFE2

100

10

BRD–EZ2–55K

6

20

12

–900HFU2, HFE2

125

10

BRD–EZ2–55K

6

20

12

–1100HFU2,
HFE2

150

10

BRD–EZ2–55K

6

20

12

–1320HFU2,
HFE2

175

10

BRD–EZ2–55K

6

20

12

Advertising