Derating curves – Hitachi L300P User Manual

Page 30

Advertising
background image

L300P Inverter

Getti

n

g Star

ted

1–11

Derating Curves

The maximum available inverter current output is limited by the carrier frequency and ambient
temperature. The carrier frequency is the inverter’s internal power switching frequency, settable
from 0.5 kHz to 12 kHz, or 0.5 kHz to 8 kHz for higher horsepower models. Choosing a higher
carrier frequency tends to decrease audible noise, but it also increases the internal heating of the
inverter, thus decreasing (derating) the maximum current output capability. Ambient tempera-
ture is the temperature just outside the inverter housing—such as inside the control cabinet
where the inverter is mounted. A higher ambient temperature decreases (derates) the inverter’s
maximum current output capacity.

Use the following derating curves to help determine the optimal carrier frequency setting for
your inverter, and to find the output current derating. Be sure to use the proper curve for your
particular L300P inverter model number.

L300P 1.5 to 22 kW 200V class

2

4

6

8

10

12

0.5

65%

70%

75%

80%

85%

90%

95%

100%

Carrier Frequency (kHz)

% of Drive’

s

Rate

d Am

ps

015L, 022L,
037L, 055L,
075L, 110L,
150L, 185L

60%

55%

110L

150L

185L

Legend:

Output current at 40

°C ambient

Output current at 50

°C ambient

220L

220L

Advertising