Output Summary Table - This table shows all 12 functions (13 for –xFU2 models) for the
logic outputs terminals [11] and [12] at a glance. Detailed function descriptions, related param-
eters and settings, and example wiring diagrams are in

“Using Intelligent Output Terminals” on

page 4–35

.

Output Function Summary Table

Option

Code

Terminal

Symbol

Function Name

Description

00

RUN

Run signal

ON

Inverter is in Run Mode, motor running

OFF

Inverter is in Stop Mode, motor stopped

01

FA1

Frequency arrival type
1 – constant speed

ON

when output to motor is at the standard set frequency
F001

OFF

when output to motor is not at the set frequency F001

02

FA2

Frequency arrival type
2 – over-frequency

ON

when output to motor is at or above the FA threshold
1(C042) during accel

OFF

when the output to motor is below the FA threshold 1
(C043) during decel

03

OL

Overload advance
notice signal (1)

ON

when output current is more than the set threshold for
the overload signal (set with C041)

OFF

when output current is less than the set threshold for
the overload signal

04

OD

Output deviation for
PID control

ON

when PID error is more than the set threshold for the
deviation signal

OFF

when PID error is less than the set threshold for the
deviation signal

05

AL

Alarm signal

ON

when the alarm condition has been met and not reset

OFF

when the alarm had not tripped since the previous
power cycle or since the previous keypad reset

06

FA3

Frequency arrival type
3 – at frequency

ON

when output to motor is at the FA threshold 1 (C042)
during accel, or at C043 during decel

OFF

when the output to motor is not at either the FA
threshold 1 (C042) during accel or at C43 during
decel

08

IP

Instantaneous power
failure signal

ON

when the inverter input power has decreased below
the acceptable input voltage level

OFF

when the inverter input power is within rated range

09

UV

Under-voltage signal

ON

when the inverter input power has decreased below
the acceptable input voltage level

OFF

when the inverter input power is within rated range

11

RNT

Operation time over

ON

when the inverter Run time exceeds the limit set by
Run/power-on warning time (B034)

OFF

when the inverter Run time is less than the limit set by
Run/power-on warning time (B034)

12

ONT

Plug-in time over

ON

when the inverter plug-in time exceeds the set limit

OFF

when the inverter plug-in time is less than the limit