Monitoring Trip Events, History, & Conditions

T

roub

leshooting

and Maintenance

6–8

Trip History and
Inverter Status

We recommend that you first find the cause of the fault before attempting clearing it. When a
fault occurs, the inverter stores important performance data at the moment of the fault. To
access the data, use the monitor functions (Dxxx) and select D081 for details about the present
fault (E

n

). The previous five faults are stored in D081 to D086, with D (E

n-1

to E

n-5

). Each error

shifts D081–D085 to D082–D086, and writes the new error to D081.

The following Monitor Menu map shows how to access the error codes. When fault(s) exist,
you can review their details by first selecting the proper function: D081 is most recent, and
D086 is the oldest.

Monitor Menu

1

Error Code

Error

exists?

Output frequency at

trip point

Motor current at

trip point

DC bus voltage at

trip point

No error

Yes

No

FUNC.

Trip History

2

1

2

2

Current Trip

Conditions

E 0 7.2

6 0.00

4.00

2 7 0.0

1 5

1 8

d

081

d

086

d

082

1

1

1

1

1

_ _ _ _

Cumulative inverter

operation time

at trip point

Cumulative power-

ON time at trip point

1

FUNC.

2

FUNC.