Appendix B

B–11

Command – 05

The 05 command reads the inverter’s trip history.
The frame format of command 05 follows the
diagrams and specification tables. The transmit
frame has no data field.

The receive frame has a 440-byte data field. This
consists of an 8-byte total accumulated number of
trip events, followed by six 72-byte strings for the
six most recent trip events as shown below.

The nine bytes of data for each trip event history is listed below. The data contains the multi-
plier to adjust the decimal point. Divide the data by that factor to derive the actual value.

Element

Description

Size

Value

STX

Control code (STart of TeXt)

1 byte

STX (0x02)

Node

Node (station) address of inverter

2 bytes 01 to 32

Command

Transmission command

2 bytes 05

BCC

Block check sum code

2 bytes Exclusive OR of Node,

Command, and Data

[CR]

Control code (carriage return)

1 byte

[CR] (0x0D)

Element

Description

Size

Value

STX

Control code (STart of TeXt)

1 byte

STX (0x02)

Node

Node (station) address of inverter

2 bytes 01 to 32

Data

Transmission data

440
bytes

(see next table)

BCC

Block check sum code

2 bytes Exclusive OR of Node,

Command, and Data

[CR]

Control code (carriage return)

1 byte

[CR] (0x0D)

No.

Monitor Item

Units

Multiplier

1

Trip factor

2

Inverter Status A

3

Inverter Status B

4

Inverter Status C

5

Output frequency

Hz

10

6

Accumulated Run Mode time

hours

1

7

Output current

A

10

8

Output voltage

V

10

9

Power ON time

hours

1

STX Node

Command

BCC [CR]

Transmit frame format

STX Node

Data

BCC [CR]

Receive frame format

Data field contents

Trip 3

Trip 2

Trip 1

Total count

Trip 6

Trip 5

Trip 4