Tables for 400v class inverters – Hitachi L300P User Manual

Page 26

Advertising
background image

L300P Inverter

Getti

n

g Star

ted

1–7

Tables for 400V
class inverters

Note that

“General Specifications” on page 1–9

covers all L300P inverters, followed by

footnotes for all specifications tables. Seven 400V models in the tables below (2 to 20 hp) have
internal dynamic braking units (see

“Dynamic Braking” on page 5–6

).

Item

200V Class Specifications, continued

L300P inverters, 200V models, UL ver.

370LFU2

450LFU2

550LFU2

750LFU2

Applicable motor size *2

HP

50

60

75

100

kW

37

45

55

75

Rated capacity (200/240V) kVA

48.4 / 58.1

58.5 / 70.2

72.7 / 87.2

93.5 / 112.2

Rated input voltage

3-phase: 200 to 240V ±10%, 50/60 Hz ±5%

Rated input current (A)

154

186

231

297

Rated output voltage *3

3-phase (3-wire) 200 to 240V (corresponding to input voltage)

Rated output current (A)

140

169

210

270

Efficiency at 100% rated output, %

95.1

95.1

95.1

95.1

Watt loss,
approximate (W)

at 70% output

1345

1625

1975

2675

at 100% output

1900

2300

2800

3800

Dynamic braking
approx. % torque,
short time stop *7

without external
braking unit

10%

10%

10%

10%

with external res.
and braking unit

45–90%

35–75%

30–60%

30–60%

DC braking

Variable operating frequency, time, and braking force

Weight

kg / lb

20 / 44

30 / 66

30 / 66

50 / 110

Item

400V Class Specifications

L300P inverters,
400V models

UL version

015HFU2

022HFU2

040HFU2

055HFU2

075HFU2

CE version

015HFE2

022HFE2

040HFE2

055HFE2

075HFE2

Applicable motor size *2

HP

2

3

5

7.5

10

kW

1.5

2.2

4.0

5.5

7.5

Rated capacity (400 / 480V) kVA

2.6 / 3.1

3.6 / 4.4

5.9 / 7.1

8.3 / 9.9

11 / 13.3

Rated input voltage

3-phase (3-wire) 380 to 480V ±10%, 50/60 Hz ±5%

Rated input current (A)

4.2

5.8

9.5

13

18

Rated output voltage *3

3-phase (3-wire): 380 to 480V (corresponding to input voltage)

Rated output current (A)

3.8

5.3

8.6

12

16

Efficiency at 100% rated output, %

92.3

93.2

94.0

94.4

94.6

Watt loss,
approximate (W)

at 70% output

102

127

179

242

312

at 100% output

125

160

235

325

425

Dynamic braking
approx. % torque,
short time stop *7

without ext. res.

50%

20%

with external res.

200%

140%

100%

DC braking

Variable operating frequency, time, and braking force

Weight

kg / lb

3.5 / 7.7

3.5 / 7.7

3.5 / 7.7

3.5 / 7.7

55 / 121