Using the Front Panel Keypad

Front Panel
Introduction

Please take a moment to familiarize yourself with the keypad layout shown in the figure below.

The display is used in programming the inverter’s parameters, as well as monitoring specific
parameter values during operation. Many functions are applicable only during the initial instal-
lation, while others are more useful for maintenance or monitoring.

Parameter Editing
and Controls

The front panel controls and indicators are described as follows:

Run/Stop LED – ON when the inverter output is ON and the motor is developing torque,

and OFF when the inverter output is OFF (Stop Mode).

Program/Monitor LED – This LED is ON when the inverter is ready for parameter editing

(Program Mode). It is normally OFF when the parameter display is monitoring data
(Monitor Mode). However, the PRG LED will be ON whenever you are monitoring the
value of parameter D001. (When the keypad is enabled as the frequency source via
A001=02, you can edit the inverter frequency directly from D001 monitor display by using
the Up/Down keys.)

Run Key Enable LED – is ON when the inverter is ready to respond to the Run key, OFF

when the Run key is disabled.

Run Key – Press this key to run the motor (the Run Enable LED must be ON first). Parame-

ter F004, Keypad Run Key Routing, determines whether the Run key generates a Run FWD
or Run REV command.

Stop/Reset Key – Press this key to stop the motor when it is running (uses the programmed

deceleration rate). This key will also reset an alarm that has tripped.

Potentiometer – allows an operator to directly set the motor speed when the potentiometer

is enabled for output frequency control.

Potentiometer Enable LED – ON when the potentiometer is enabled for value entry.

Parameter Display – a 4-digit, 7-segment display for parameters and function codes.

Display Units: Hertz/Volts/Amperes/kW/% – These LEDs indicate the units associated

with the parameter display. When the display is monitoring a parameter, the appropriate
LED is ON. In the case of kW units, both Volts and Amperes LEDs will be ON. An easy way
to remember this is that kW = (V x A)/1000.

Power LED – This LED is ON when the power input to the inverter is ON.

Alarm LED – This LED is ON when an alarm condition has tripped the inverter. Clearing

the alarm will turn this LED OFF again. See Chapter 6 for details on clearing alarms.

Hz

POWER

A

RUN

PRG

RUN

STOP

RESET

MIN

MAX

HITACHI

FUNC

1

2

%

ALARM

STR

V

kW

Run/Stop LED

Program/Monitor LED

Run Key Enable LED

Run Key

Power LED

Alarm LED

Display Units LEDs

Hertz
Volts or Amperes
(kW = both ON)
Percent

Parameter Display

Potentiometer Enable LED

Potentiometer

Stop/Reset Key