L300p dynamic braking selection tables – Hitachi L300P User Manual

Page 197

Advertising
background image

L300P Inverter

Motor C

ontrol

Acc

e

ssor

ies

5–7

L300P
Dynamic Braking
Selection Tables

The L300P Series 200V and 400V class inverter models in the 2 to 20 hp range have internal
braking units. Additional stopping torque is available by adding external resistors. The required
braking torque depends on your particular application. Other tables in this section will help you
choose the proper resistor.

2 to 20 hp (1.5 to 15 kW)

Using

Internal Resistor

Using Optional

External Resistor

Performance @

Minimum Resistance

Minimum

Resistance

@ 100%

Braking

Duty

Cycle,

Ohms

Voltage

Class

Model Number,

L300P

Motor

hp

Braking

Unit

Braking

Torque

@ 60Hz,
(without

external

resistor),

%

External

Resistance,

Ohms

Braking

Torque

@60Hz,

%

Minimum

Resistance,

Ohms

Max.

Braking

Duty

Cycle,

%

200V

–015LFU2

2

Built-in

50

35

200

35

10

100

–022LFU2

3

Built-in

20

35

160

35

10

100

–037LFU2

5

Built-in

20

35

100

35

10

100

–055LFU2

7.5

Built-in

20

17

80

17

10

50

–075LFU2

10

Built-in

20

17

80

17

10

50

–110LFU2

15

Built-in

10

17

55

17

10

50

–150LFU2

20

Built-in

10

17

50

17

10

50

400V

–015HFU2, HFE2

2

Built-in

50

100

200

100

10

300

–022HFU2, HFE2

3

Built-in

20

100

200

100

10

300

–037HFU2, HFE2

5

Built-in

20

100

140

70

10

200

–055HFU2, HFE2

7.5

Built-in

20

70

100

70

10

200

–075HFU2, HFE2

10

Built-in

20

70

100

50

10

150

–110HFU2, HFE2

15

Built-in

10

70

55

50

10

150

–150HFU2, HFE2

20

Built-in

10

70

50

50

10

150

Advertising