Multi-speed and jog frequency settings – Hitachi L300P User Manual

Page 82

Advertising
background image

L300P Inverter

Configur

ing Dr

iv

e

P

a

ra

met

e

rs

3–13

Multi-speed and
Jog Frequency
Settings

The L300P inverter has the capability to store and output up to 16 preset frequencies to the
motor (A020 to A035). As in traditional motion terminology, we call this multi-speed profile
capability. These preset frequencies are selected by means of digital inputs to the inverter. The
inverter applies the current acceleration or deceleration setting to change from the current
output frequency to the new one. The first multi-speed setting is duplicated for the second
motor settings (the remaining 15 multi-speeds apply only to the first motor).

The jog speed setting is used whenever the Jog command is active. The jog speed setting range
is arbitrarily limited to 10 Hz to provide safety during manual operation. The acceleration to the
jog frequency is instantaneous, but you can choose from six modes for the best method for
stopping the jog operation.

“A” Function

Run

Mode

Edit

Lo Hi

Defaults

Units

SRW Display

Func.

Code

Name

Description

–FE2

(CE)

–FU2

(UL)

–FR

(Jpn)

A019 Multi-speed operation

selection

Two options; select codes:
00 Binary; up to 16-stage

speed using 4 intelligent
terminals

01 Single-bit; up to 8-stage

speed using 7 intelligent
terminals

✘ ✘

00

00

00

>A019 SPEED

SELECT BINARY

A020 Multi-speed frequency

setting

Defines the first speed of a
multi-speed profile, range is
0 to 360 Hz
A020 = Speed 1 (1st motor)

✔ ✔ 0.00 0.00 0.00

Hz

>A020 SPEED

FS 0000.00Hz

A220 Multi-speed frequency

setting, 2nd motor

Defines the first speed of a
multi-speed profile for 2nd
motor, range is 0 to 360 Hz
A220 = Speed 1 (2nd motor)

✔ ✔ 0.00 0.00 0.00

Hz

>A220 SPEED

2FS 0000.00Hz

A021
to
A035

Multi-speed frequency
settings
(for both motors)

Defines 15 more speeds,
range is 0 to 360 Hz.
A021 = Speed 2...
A035 = Speed 16

✔ ✔ 0.00 0.00 0.00

Hz

>A021 SPEED

01S 0000.00Hz

A038 Jog frequency setting

Defines limited speed for
jog, range is 0.5 to 9.99 Hz

✔ ✔ 1.00 1.00 1.00

Hz

>A038 Jogging

F 01.00Hz

A039 Jog stop mode

Define how end of jog stops
the motor; six options:
00 Free-run stop, jogging

disabled during motor
run

01 Controlled deceleration,

jogging disabled during
motor run

02 DC braking to stop,

jogging disabled during
motor run

03 Free-run stop, jogging

always enabled

04 Controlled deceleration,

jogging always enabled

05 DC braking to stop,

jogging always enabled

✘ ✔

00

00

00

>A039 Jogging

Mode FRS

Advertising