“A” Group: Standard Functions

Configur

ing Dr

iv

e

P

a

ra

meters

3–26

The acceleration and deceleration curves can deviate from a straight line to a varying degree.
Parameters A131 and A132 control the amount of deviation for the acceleration and decelera-
tion curves respectively. The following graphs show intermediate output frequency points as a
percentage of the target frequency, for 25%, 50%, and 75% acceleration time intervals.

time

Output frequency

25

50

75

% of target

time

Output frequency

25

50

75

% of target

time

Output frequency

25

50

75

% of target

3.1

17.6

82.4

96.9

100

100

100

99.6

93.8
87.5

68.4
64.6

35.0

65.0

35.4
31.6

12.5
6.25
0.39

“A” Function

Run

Mode

Edit

Lo Hi

Defaults

Units

SRW Display

Func.

Code

Name

Description

–FE2

(CE)

–FU2

(UL)

–FR

(Jpn)

A131 Acceleration curve

constants setting

Sets the curve deviation
from straight-line accelera-
tion in ten levels:
01 smallest deviation
10 largest deviation

✘ ✔

02

02

02

>A131 ACCEL

GAIN 02

A132 Deceleration curve

constants setting

Sets the curve deviation
from straight-line decelera-
tion in ten levels:
01 smallest deviation
10 largest deviation

✘ ✔

02

02

02

>A132 DECEL

GAIN 02