Asynchronous initialization, Byte-oriented synchronous mode – Zilog Z80230 User Manual

Page 105

Advertising
background image

SCC/ESCC

User Manual

UM010903-0515

Data Communication Modes

98

the state of WR7' D3. The RCA bit is set if there is at least one byte available, regardless of the

status of WR7' bit D3.

This is the initialization sequence for the receiver in Asynchronous mode. First, WR4 selects the

mode, then WR3 and WR5 select the various options. At this point, the other registers should be

initialized as necessary. When all of this is complete, the receiver may be enabled by setting bit D0

of WR3 to 1.

See

The Receiver Interrupt

on page 45 for more details on receive interrupts.

Asynchronous Initialization

The initialization sequence for Asynchronous mode is listed in

Table

. All of the SCC’s registers

should be re-initialized after a channel or hardware reset. Also, WR4 should be programmed first

after a reset.

At this point, the other registers should be initialized according to the hardware design such as

clocking, I/O mode, etc. When this is completed, the transmitter is enabled by setting WR5 bit D3

to 1 and the receiver is enabled by setting WR3 bit D0 to 1.

Byte-Oriented Synchronous Mode

The SCC supports three byte-oriented synchronous protocols. They are: monosynchronous, bisyn-

chronous, and external synchronous.

Initialization Sequence Asynchronous Mode

Reg

Bit No

Description

WR9

6, 7

Hardware or channel Reset

WR4

3, 2

Select Async Mode and the

number of stop bits*

0, 1

Select parity*

6, 7

Select clock mode*

WR3

7, 6

Select number of receive bits per

character

5

Select Auto Enables Mode*

WR5

6, 5

Select number of bits/char for

transmitter

1

Select modem control (RTS)

Note: * Initializes transmitter and receiver simultaneously.