Dpll operation in the manchester mode – Zilog Z80230 User Manual

Page 89

Advertising
background image

SCC/ESCC

User Manual

UM010903-0515

SCC/ESCC Ancillary Support Circuitry

82

If no transition occurs between the middle of count 12 and the middle of count 19, the DPLL is

probably not locked onto the data properly. When the DPLL misses an edge, the One Clock Miss-

ing bit is RR10, it is set to 1 and latched. It will hold this value until a Reset Missing Clock com-

mand is issued in WR14, or until the DPLL is disabled or programmed to enter the Search mode.

Upon missing this one edge, the DPLL takes no other action and does not modify its count during

the next counting cycle.

If the DPLL does not see an edge between the middle of count 12 and the middle of count 19 in

two successive 0 to 31 count cycles, a line error condition is assumed. If this occurs, the Two

Clocks Missing bit in RR10 is set to 1 and latched. At the same time, the DPLL enters the Search

mode. The DPLL makes the decision to enter the Search mode during count 2, where both the

receive clock and transmit clock outputs are Low. This prevents any glitches on the clock outputs

when the Search mode is entered. While in the Search mode, no clock outputs are provided by the

DPLL. The Two Clocks Missing bit in RR10 is latched until a Reset Missing Clock command is

issued in WR14, or until the DPLL is disabled or programmed to enter the Search mode.

While the DPLL is disabled, the transmit clock output of the DPLL may be toggled by alternately

selecting FM and NRZI mode in the DPLL. The same is true of the receive clock.

While the DPLL is in the Search mode, the counter remains at count 16 where the receive output is

Low and the transmit output is Low. This fact is used to provide a transmit clock under software

control since the DPLL is in the Search mode while it is disabled.

As in NRZI mode, if an adjustment to the counting cycle is necessary, the DPLL modifies count 5,

either deleting it or doubling it. If no adjustment is necessary, the count sequence proceeds nor-

mally.

When the DPLL is programmed to enter Search mode, only clock transitions should exist on the

receive data pin. If this is not the case, the DPLL may attempt to lock on to the data transitions. If

the DPLL does lock on to the data transitions, then the Missing Clock condition will inevitably

occur because data transitions are not guaranteed every bit cell.

To lock in the DPLL properly, FM0 encoding requires continuous 1s received when leaving the

Search mode. In FM1 encoding, continuous 0s are required; with Manchester encoded data this

means alternating 1s and 0s. With all three of these data encoding methods there is always at least

one transition in every bit cell, and in FM mode the DPLL is designed to expect this transition.

DPLL Operation in the Manchester Mode

The SCC can be used to decode Manchester data by using the DPLL in the FM mode and pro-

gramming the receiver for NRZ data. Manchester encoded data contains a transition at the center

of every bit cell; it is the direction of this transition that distinguishes a 1 from a 0. Hence, for

Manchester data, the DPLL should be in FM mode (WR14 command D7=1, D6=1, D5=0), but the

receiver should be set up to accept NRZ data (WR10 D6=0, D5=0).