SCC/ESCC

User Manual

UM010903-0515

Data Communication Modes

134

mode, and then WR10 to select the CRC preset value and program the Mark/Flag idle bit. The

Loop Mode and Go-Active-On-Poll bits in WR10 should not be set to 1 yet. The flag is written in

WR7 and the various options are selected in WR3 and WR5. At this point, the other registers are

initialized as necessary (

Table

).

The Loop Mode bit (D1) in WR10 is set to 1. When all of this is complete, the transmitter is

enabled by setting bit D3 of WR5 to 1. Now that the transmitter is enabled, the CRC generator is

initialized by issuing the Reset Tx CRC Generator command in WR0. The receiver is enabled by

setting the Go-Active-On-Poll bit (D4) in WR10 to 1. The SCC goes on the loop when seven con-

secutive 1s are received, and signals this by setting the On-Loop bit in RR10. Note that the seven

consecutive 1s will set the Break/Abort and Hunt bits in RR0 also. Once the SCC is on the loop,

the Go-Active-On-Poll bit should be set to 0 until a message is to be transmitted on the loop. To

transmit a message on the loop, the Go-Active-On-Poll bit should be set to 1. At this point, the

SDLC Loop Mode Initialization

Bit Number

Reg

D7 D6 D5 D4 D3 D2 D1 D0 Description

WR4 0

0

1

0

0

0

0 0

Select x1 clock, SDLC mode, enable sync

mode

WR3 r

x

0

1

1

1

0 0

rx=# of Rx bits/char, No auto enable, enter

Hunt, Enable Rx CRC, Address Search,

No sync character load inhibit

WR5 d

t

x

0

0

0

r

1

d=inverse of DTR pin, tx=# of Tx bits/char,

use SDLC CRC, r=inverse state of /RTS

pin, CRC enable

WR7 0

1

1

1

1

1

1 0

SDLC Flag

WR6 x

x

x

x

x

x

x x

Receiver secondary address

WR15 x

x

x

x

x

x

x 1

Enable access to new register

WR7' 0

1

1

d

1

r

1 1

Enable extended read, Tx INT on FIFO

empty, d=REQUEST timing mode, Rx INT

on 4 char, r=RTS deactivation, auto EOM

reset, auto flag tx

WR10 c

d

e

1

i

0

1 0

Enable Loop Mode, Go Active On Poll,

c=CRC preset, de=data encoding method,

i=idle line

WR3 r

x

0

1

1

1

0 1

Enable Receiver

WR5 d

t

x

0

1

0

r

1

Enable Transmitter

WR0 1

0

0

0

0

0

0 0

Reset CRC generator