SCC/ESCC

User Manual

UM010903-0515

SCC/ESCC Ancillary Support Circuitry

73

The BRG is enabled while bit D0 of WR14 is set to 1. It is disabled while WR14 D0=0 and after a

hardware reset (but not a software reset). To prevent metastable problems when the baud rate gen-

erator is first enabled, the enable bit is synchronized to the baud rate generator clock. This intro-

duces an additional delay when the baud rate generator is first enabled (

Figure

). The baud rate

generator is disabled immediately when bit D0 of WR14 is set to 0, because the delay is only nec-

essary on start-up. The baud rate generator is enabled and disabled on the fly, but this delay on

start-up must be taken into consideration.

Baud Rate Generator Start Up

The formulas relating the baud rate to the time-constant and vice versa are shown below.

In these formulas, the BRG clock frequency (PCLK or /RTxC) is in Hertz, the desired baud rate in

bits/sec, Clock Mode is 1 in sync modes, 1, 16, 32 or 64 in async mode and the time constant is

dimensionless. The example in

Table

assumes a 2.4576 MHz clock (from /RTxC) factor of 16 and

shows the time constant for a number of popular baud rates.

For example:

Time Constant

Clock Frequency

2

Clock Mode

Baud Rate

-------------------------------------------------------------------------------- 2

=

Baud Rate

Clock Frequency

2

Clock Mode

Time Constant 2

+

----------------------------------------------------------------------------------------------------

=