Transmit clock counter (escc only), Clock selection – Zilog Z80230 User Manual

Page 90

Advertising
background image

SCC/ESCC

User Manual

UM010903-0515

SCC/ESCC Ancillary Support Circuitry

83

Transmit Clock Counter (ESCC only)

The ESCC includes a Transmit Clock Counter which parallels the DPLL. This counter provides a

jitter-free clock source to the transmitter by dividing the DPLL clock source by the appropriate

value for the programmed data encoding format as displayed in

Figure

. Therefore, in FM mode

(FM0 or FM1), the counter output is the input frequency divided by 16. In NRZI mode, the coun-

ter frequency is the input divided by 32. The counter output replaces the DPLL transmit clock out-

put, available as the transmit clock source. This has no effect on the use of the DPLL as the receive

clock source.

The output of the transmit clock derived from this counter is available to the /TRxC pin when the

DPLL output is selected as the transmit clock source. Care must be taken using ESCC in SDLC

Loop mode with the DPLL. The SDLC Loop mode requires synchronized Tx and Rx clocks, but

the ESCC’s DPLL might be off-sync because of this Transmit Clock Counter. In SDLC Loop, one

should instead echo the signal of the RxDPLL out to clock the receiver and transmitter to achieve

synchronization. This can be programmed via bits D1-D0 in WR11.

DPLL Transmit Clock Counter Output (ESCC only)

Clock Selection

The SCC can select several clock sources for internal and external use. Write Register 11 is the

Clock Mode Control register for both the receive and transmit clocks. It determines the type of

signal on the /SYNC and /RTxC pins and the direction of the /TRxC pin.

The SCC is programmed to select one of several sources to provide the transmit and receive

clocks.

The source of the receive clock is controlled by bits D6 and D5 of WR11. The receive clock may

be programmed to come from the /RTxC pin, the /TRxC pin, the output of the baud rate generator,

or the receive output of the DPLL.

The source of the transmit clock is controlled by bits D4 and D3 of WR11. The transmit clock may

be programmed to come from the /RTxC pin, the /TRxC pin, the output of the baud rate generator,

or the transmit output of the DPLL.

DPLL

DPLL Counter

Input Divided by 16 (FM0 or FM1)

Input Divided by 32 for NRZI

DPLL Output to Receiver

DPLL Output to Transmitter

DPLL CLK

Input

Advertising