Read register 2, Table – Zilog Z80230 User Manual

Page 187

Advertising
background image

SCC/ESCC

User Manual

UM010903-0515

Register Descriptions

180

Bit 0: All Sent status

In Asynchronous mode, this bit is set when all characters have completely cleared the transmitter

pins. Most modems contain additional delays in the data path, which requires the modem control

signals to remain active until after the data has cleared both the transmitter and the modem. This

bit is always set in synchronous and SDLC modes.

Read Register 2

RR2 contains the interrupt vector written into WR2. When the register is accessed in Channel A,

the vector returned is the vector actually stored in WR2. When this register is accessed in Channel

B, the vector returned includes status information in bits 1, 2 and 3 or in bits 6, 5 and 4, depending

on the state of the Status High/Status Low bit in WR9 and independent of the state of the VIS bit

in WR9. The vector is modified according to

Table

on page 161 listed in the explanation of the

VIS bit in WR9 (See

Write Register 8 (Transmit Buffer)

on page 159). If no interrupts are pending,

the status is V3,V2,V1 -011, or V6,V5,V4-110.

Figure

on page 181 the bit positions for RR2.

1

0

1

0

7

0

1

1

0

8

1

1

1

1

8

0

0

0

2

8

Bits per Character Residue Decoding

Bits per Character

Bit 3

Bit 2

Bit 1

8

0

1

1

7

0

0

0

6

0

1

0

5

0

0

1

I-Field Bit Selection (8 Bits Only) (Continued)

Bit 3 Bit 2

Bit 1

I-Field Bits in

Last Byte

I-Field Bits in Previous Byte

Advertising