External/status interrupts – Zilog Z80230 User Manual

Page 63

Advertising
background image

SCC/ESCC

User Manual

UM010903-0515

Interfacing the SCC/ESCC

56

External/Status Interrupts

Each channel has six external/status interrupt conditions: BRG Zero Count, Data Carrier Detect,

Sync/Hunt, Clear to Send, Tx Underrun/EOM, and Break/Abort. The master enable for external/

status interrupts is D0 of WR1, and the individual enable bits are in WR15. Individual enable bits

control whether or not a latch is present in the path from the source of the interrupt to the corre-

sponding status bit in RR0. If the individual enable is set to 0, then RR0 reflects the current

unlatched status, and if the individual enable is set to 1, then RR0 reflects the latched status.

The latches for the external/status interrupts are not independent. Rather, they all close at the same

time as a result of a state change in one of the sources of enabled external/status interrupts. This is

displayed schematically in

Figure

on page 57.

The External/Status IP is set by the closing of the latches and remains set as long as they are

closed. In order to determine which condition(s) require service when an external/status interrupt

is received, the processor should keep an image of RR0 in memory and update this image each

time it executes the external/status service routine.

Thus, a read of RR0 returns the current status for any bits whose individual enable is 0, and either

the current state or the latched state of the remainder of the bits. To guarantee the current status,

the processor should issue a Reset External/Status interrupts command in WR0 to open the

latches. The External/Status IP is set by the closing of the latches and remains set as long as they