SCC I/O Read/Write Cycle

Assume that the Z180 MPU’s /IOC bit in the OMCR (Operation Mode Control Register) clears to

0 (this condition is a Z80

®

compatible timing mode for /IORQ and /RD). The following are sev-

eral design points to consider (also see Table on page 214).

I/O Read Cycle

Parameters 8 and 9 explains that Address is stable 20 ns before the falling edge of /RD and until /

RD goes inactive.
Parameters 19 and 20 explains that /CE is stable at the falling edge of /RD and until /RD goes

inactive.
Parameter 22 explains the /RD pulse width is wider than 125 ns.
Parameters 25 and 27 explains that Read data is available on the data bus 120 ns later than the fall-

ing edge of /RD and 180 ns from a stable Address.

I/O Write Cycle

Parameters 6 and 7 explains that Address is stable 50 ns before the falling edge of /WR and is sta-

ble until /WR goes inactive.
Parameters 16 and 17 explains that /CE is stable at the falling edge of /WR and is stable until /W

goes inactive.
Parameter 28 explains /WR pulse width is wider than 125 ns.
Parameters 28 and 29 explains that Write data is on the data bus 10 ns before the falling edge of /

WR. It is stable until the rising edge of /WR.
Table and Table list the worst case SCC parameters calculating Z180 parameters at 10 MHz.

20 ThCE(RD)

/CE to /RD High Hold

0

ns

22 TwRDI

/RD Low Width

125

ns

25 TdRDf(DR)

/RD Low to Read Data Valid

120

ns

27 TdA(DR)

Address to Read Data Valid

180

ns

28 TwWRI

/WR Low Width

125

ns

29 TsDW(WR)

Write Data to /WR Low Setup

10

ns

30 TdWR(W)

Write Data to /WR High Hold

0

ns

10 MHz SCC Timing Parameters for I/O Read/Write Cycle (Worst Case)

No Symbol

Parameter

Min

Max

Units