Scc/escc user manual – Zilog Z80230 User Manual

Page 254

Advertising
background image

SCC/ESCC

User Manual

UM010903-0515

Application Notes

247

Test Program–Z180/SCC DMA Transfer (Continued)

db

01h

;select WR1

db

01100000b

;REQ on Rx

db

02h

;select WR2

db

00h

;00h as vector base

db

03h

;select WR3

db

11000000b

;Rx 8bit/char

db

05h

;select WR5

db

01100000b

;tx 8bit/char

db

06h

;select WR6

db

00h

;

db

07h

;select WR7

db

00h

;

db

09h

;select WR9

db

00000001b

;stat low, vis

db

0ah

;select WR10

db

00000000b

;set as default

db

0bh

;select WR11

db

01010110b

;

;

0

No xtal

;

1010

TxC,RxC from BRG

;

110

TRxC = BRG output

db

0ch

;select WR12

db

00h

;BR TC Low

db

0dh

;select WR12

db

00h

;BR TC high

db

0eh

;select WR14

db

00010110b

;

;

000

nothing about DPLL

;

1

Local loopback

;

0

No local echo

;

1

DTR/REQ is req

;

1

BRG source = PCLK

;

0

Not enabling BRG yet

db

0eh

;select WR14

db

00010111b

;

;

000

nothing about DPLL

;

1

Local loopback

;

0

No local echo

;

1

DTR/REQ is REQ

;

1

BRG source = PCLK

;

1

Enable BRG

db

03h

;select WR3

db

11000001b

;rx enable