Application Notes

267

Finally, an unpopulated 4-pin oscillator socket is included on the board with its output connected

to a single jumper/wire-wrap pin. This socket can be populated with a user-supplied oscillator and 

connected to various clock pins among J5-J15.

Sensing Which Serial Controller Channel is Connected to the Console

To use the software provided with this evaluation board, one of the serial controller channels must

be connected to a PC or a dumb terminal via the J1 and J13 connectors. Some versions of this soft-

ware may restrict the choice to (E)SCC Channel A or (M)USC, depending on your application

needs. There is nothing in the hardware that limits the choice of which serial channel is used for

the console. However, on the J1-J4 (J13-J15) side, there are two things that are special about the

J1-J13 section as compared to the others. One is the provision for a Non-Maskable Interrupt in

response to a received Start bit, as described in addressing on page 257 .
Software can use the other special feature of the J1/J13 section, after a Reset, to sense which serial

channel is connected to the Console port. A Reset signal (from power-on or Reset button but not

from the Reset-The-ISCC, address decode (and others) described earlier) places the "NMI" EPLD

in a special mode where the first Start bit on the Consoles Transmit Data lead causes an NMI. This

feature can be used in a start-up procedure like the following example, to determine which serial

controller channel is used for the Console.
For each serial controller channel that the software can use for the Console:

1. Initialize the channel.
2. Send NULL character to the channel.
3. Wait for a short time to see if an NMI occurs. If an NMI occurs., the current channel is

the Console otherwise go on to the next serial channel and try again.

4

Port0 (Clock 0 In)

Port0

5

N/C

N/C

6

Port3 (Rcv TSA Gate Out)

Port3 (Rcv TSA Gate Out)

7

N/C

(SYSCLK)

8

Port5 (Rcv Sync Out)

Port5 (Rcv Sync Out)

9

Port2

Port2

10

GND

GND

11

PORT6 (Rcv Sync IN)

PORT6 (Rcv Sync IN)

12

Port7 (Xmit Complete Out)

Port7 (Xmit Complete Out)

Pin Assignments of Controller Port Connectors (Continued)

Pin No

J11:IUSC Signal

J12: (M)USC Signal