223

Z180 to SCC Interface

The following subsections discuss the various parameters between the Z180/SCC interface:

CPU hardware

I/O operation (read/write)

SCC interrupts

Z80 interrupt daisy-chain operation

SCC interrupt daisy-chain operation

I/O cycles

CPU Hardware Interfacing

The hardware interface has three basic groups of signals:

1. Data bus
2. System control
3. Interrupt control.

For more detailed signal information, refer to Zilog’s Technical Manuals, and Product Specifica-

tions for each device.

Data Bus Signals

D7-D0:

Data bus (Bidirectional, tri-state). This bus transfers data between the Z180 and SCC.

System Control Signals

A//B, C//D:

Register select signals (Input). These lines select the registers.

/CE:

Chip enable (Input, active Low). /CE selects the proper peripheral for programming. /CE is gated

with /IORQ or /MREQ to prevent false chip selects during other machine cycles.

/RD+

Read (input, active Low). /RD activates the chip-read circuitry and gates data from the chip onto

the data bus.

/WR+

Write (Input, active Low). /WR strobes data from the data bus into the peripheral.

Chip reset occurs when /RD and /WR are active simultaneously.