Register Descriptions

168

advisable to disable the baud rate generator while the new time constant is loaded into WR12 and

WR13. Ordinarily, this is done anyway to prevent a load of the down counter between the writing

of the upper and lower bytes of the time constant.

The formula for determining the appropriate time constant for a given baud is shown below, with

the desired rate in bits per second and the BR clock period in seconds. This formula is derived

because the counter decrements from N down to zero-plus-one-cycle for reloading the time con-

stant. This is then fed to a toggle flip-flop to make the output a square wave. Bit positions for

WR12 are displayed in

Figure

on page 168.

Write Register 12

Time Constant

Clock Frequency

2

Desired

R

ate

BR Clock Period

------------------------------------------------------------------------------------------------- 2

=

D7 D6 D5 D4 D3 D2 D1 D0

Write Register 12

TC0
TC1
TC2
TC3
TC4
TC5
TC6
TC7

Lower Byte of

Time Constant