set timezone

253

Examples — The following command sets the date to March 13, 2003
and time to 11:11:12:

WX4400# set timedate date feb 29 2004 time 23:58:00

Time now is: Sun Feb 29 2004, 23:58:02 PST

See Also

„

clear summertime on page 193

„

clear timezone on page 194

„

display summertime on page 212

„

display timedate on page 213

„

display timezone on page 213

„

set summertime on page 250

„

set timezone on page 253

set timezone

Sets the number of hours, and optionally the number of minutes, that the
WX real-time clock is offset from Coordinated Universal Time (UTC).
These values are also used by Network Time Protocol (NTP), if it is
enabled.

Syntax

set timezone

zone-name

{

-

hours

[

minutes

]}

„

zone-name

— Time zone name of up to 32 alphabetic characters. You

can use a standard name or any name you like.

„

-

(minus sign) — Minus time to indicate hours (and minutes) to be

subtracted from UTC. Otherwise, hours and minutes are added by
default.

„

hours

— Number of hours to add or subtract from UTC.

„

minutes

— Number of minutes to add or subtract from UTC.

Defaults — If this command is not used, then the default time zone is
UTC.

Access — Enabled.

History —Introduced in MSS Version 3.0.