display log trace

763

display log trace

Displays system information stored in the nonvolatile log buffer or the
trace buffer.

Syntax

display log trace [{+|-|/}number-of-messages]

[facility facility-name] [matching string]

[severity severity-level]

„

trace

— Displays the log messages in the trace buffer.

„

+

|-|/number-of-messages

— Displays the number of messages

specified as follows:

„

A positive number (for example, +100), displays that number of log
entries starting from the oldest in the log.

„

A negative number (for example, -100) displays that number of log
entries starting from newest in the log.

„

A number preceded by a slash (for example, /100) displays that
number of the most recent log entries in the log, starting with the
least recent.

„

facility

facility-name

Area of MSS that is sending the log

message. Type a space and a question mark (?) after display log
trace facility
for a list of valid facilities.

„

matching

string

Displays messages that match a string—for

example, a username or IP address.

„

severity

severity-level

Displays messages at a severity level

greater than or equal to the level specified. Specify one of the
following:

„

emergency

— The WX switch is unusable.

„

alert

— Action must be taken immediately.

„

critical

— You must resolve the critical conditions. If the

conditions are not resolved, the WX can reboot or shut down.

„

error

— The WX is missing data or is unable to form a connection.

„

warning

A possible problem exists.

„

notice

— Events that potentially can cause system problems have

occurred. These are logged for diagnostic purposes. No action is
required.

„

info

— Informational messages only. No problem exists.

„