set radius

631

MSS encrypts the display form of the string in display config and
display aaa output.

„

retransmit

number

— Number of transmission attempts the WX

switch makes before declaring an unresponsive RADIUS server
unavailable. You can specify from 1 to 100 retries.

„

timeout

seconds

— Number of seconds the WX switch waits for the

RADIUS server to respond before retransmitting. You can specify from
1 to 65,535.

Defaults — Global RADIUS parameters have the following default
values:

„

deadtime — 0 (zero) minutes (The WX switch does not designate
unresponsive RADIUS servers as unavailable.)

„

encrypted-key—No key

„

key — No key

„

retransmit — 3 (the total number of attempts, including the first
attempt)

„

timeout — 5 seconds

Access — Enabled.

History —Introduced in MSS Version 3.0. The encrypted-key option
was added in Version 4.2.

Usage — You can specify only one parameter per command line.

Examples — The following commands sets the dead time to 5 minutes,
the RADIUS key to goody, the number of retransmissions to 1, and the
timeout to 21 seconds on all RADIUS servers connected to the WX
switch:

WX1200# set radius deadtime 5

success: change accepted.

WX1200# set radius key goody

success: change accepted.

WX1200# set radius retransmit 1

success: change accepted.

WX1200# set radius timeout 21

success: change accepted.