95 part 4 commands – IAI America XSEL-KET User Manual

Page 114

Advertising
background image

95

Part 4 Commands

INTELLIGENT ACTUATOR


Operation type in the output field
CC: Command was executed successfully, ZR: Operation result is zero,
PE: Operation is complete, CP: Command part has passed, TU: Time up
EQ: Operand 1 = Operand 2, NE: Operand 1

 Operand 2,

GT: Operand 1 > Operand 2, GE: Operand 1

 Operand 2,

LT: Operand 1 < Operand 2, LE: Operand 1

 Operand 2

Category

Condition Command

Operand 1

Operand 2

Output

Function

Page

Optional BGPA

Palletizing

number

Prohibited

CP

Declare start of palletizing
setting

218

Optional EDPA

Prohibited

Prohibited

CP

Declare end of palletizing
setting

218

Optional PAPI

Count

Count

CP

Set palletizing counts

219

Optional

PAPN

Pattern number

Prohibited

CP

Set palletizing pattern

219

Optional

PASE

Axis number

Axis number

CP

Set palletizing axes

220

Optional PAPT

Pitch

Pitch

CP

Set

palletizing

pitches

220

Optional

PAST

(Position number)

Prohibited

CP

Set palletizing reference point

221

Optional PAPS

Position

number

Prohibited

CP

Set 3 palletizing points for
teaching

222

Optional

PSLI

Offset amount

(Count)

CP

Set zigzag

226

Optional

PCHZ

(Axis number)

Prohibited

CP

Set palletizing Z-axis

227

Optional

PTRG

Position number

Position number

CP

Set palletizing arch triggers

228

Optional

PEXT

(Position number)

Prohibited

CP

Set palletizing composition

229

Optional

OFPZ

Offset amount

Prohibited

CP

Set palletizing Z-axis offset

229

Optional

ACHZ

Axis number

Prohibited

CP

Declare arch-motion Z-axis

230

Optional

ATRG

Position number

Position number

CP

Set arch triggers

231

Optional

AEXT

(Position number)

Prohibited

CP

Set arch-motion composition

232

Optional

OFAZ

Offset amount

Prohibited

CP

Set arch-motion Z-axis offset

232

Optional

PTNG

Palletizing number

Variable number

CP

Get palletizing position number

233

Optional PINC

Palletizing

number

Prohibited

CC

Increment palletizing position
number by 1

233

Optional PDEC

Palletizing

number

Prohibited

CC

Decrement palletizing position
number by 1

234

Optional PSET

Palletizing

number

Data

CC

Set palletizing position number
directly

234

Optional

PARG

Palletizing number

Axis number

CP

Get palletizing angle

235

Optional

PAPG

Palletizing number

Position number

CP

Get palletizing calculation data

235

Optional

PMVP

Palletizing number

(Position number)

PE

Move to palletizing points via
PTP

236

Optional

PMVL

Palletizing number

(Position number)

PE

Move to palletizing points via
interpolation

237

Optional

PACH

Palletizing number

Position number

PE

Palletizing-point arch motion

238

Palletizing-

related

Optional ARCH

Position

number

Position number

PE

Arch motion

240

Extension conditions LD (LOAD), A (AND), O (OR), AB (AND BLOCK) and OB (OR BLOCK) are supported.

Optional

CHPR

0 or 1

Prohibited

CP

Change task level

242

Prohibited

TPCD

0 or 1

Prohibited

CP

Specify processing to be
performed when input condition
is not specified

242

Optional

TSLP

0 or 1

Prohibited

CP

Task sleep

243

Optional

OUTR

Output, flag number

Prohibited

CP

Output relay for ladder

See

265

Building of

pseudo-

ladder task

Optional

TIMR

Local flag number

Timer setting

CP

Timer relay for ladder

See

265

Advertising