Part 4 Commands

INTELLIGENT ACTUATOR



GVEL (Get speed data)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional GVEL

Variable

number

Position

number

CP

[Function] Obtain speed data from the speed item in the position data specified in operand 2, and set

the value in the variable specified in operand 1.


[Example]

GVEL

100

10

Set the speed data at position No. 10 in variable 100.


Position No.

Axis 1

Axis 2

Axis 3

Vel

Acc

Dcl

1 XXX.XXX

XXX.XXX

XXX.XXX

XXX

X.XX

X.XX

2 XXX.XXX

XXX.XXX

XXX.XXX

XXX

X.XX

X.XX




10 50.000

100.000

150.000

200

0.30

0.30



If the position data is set as above when the command is executed, 200 will be set in variable 100.