IAI America XSEL-KET User Manual

Page 383

Advertising
background image

364

INTELLIGENT ACTUATOR

Appendix


Other Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

37 PC/TP data protect

setting (Position)

0H 0H

~

FFFFFFFFH

Bits 0 to 3:

Protect type (0: Read/write, 1: Read
only, 2: No read/write)

Bits 4 to 7:

Protect release method (0: Special
operation)

Bits 8 to 11: Protect range maximum number (10’s

place, BCD)

Bits 12 to 15: Protect range maximum number (100’s

place, BCD)

Bits 16 to 19: Protect range maximum number

(1000’s place, BCD)

Bits 20 to 23: Protect range minimum number (10’s

place, BCD)

Bits 24 to 27: Protect range minimum number (100’s

place, BCD)

Bits 28 to 31: Protect range minimum number

(1000’s place, BCD)

* The value in the 1’s place is considered “0” for

both the protect range maximum/minimum
numbers.

* Referenced by the PC/TP (PC software version

2.0.0.42 or later and TP application version 1.09 or
later)

38 PC/TP data protect

setting (Symbol,
parameter)

0H 0H

~

FFFFFFFFH

Bits 0 to 3:

Protect type (Parameter) (0:
Read/write, 1: Read only, 2: No
read/write)

Bits 4 to 7:

Protect release method (Parameter) (0:
Special operation)

Bits 8 to 11: Protect type (Symbol) (0: Read/write, 1:

Read only, 2: No read/write)

Bits 12 to 15: Protect release method (Symbol) (0:

Special operation)

* Referenced by the PC/TP (PC software version

2.0.0.42 or later and TP application version 1.09 or
later)

39 (For

future

extension)

0H 0H

~

FFFFFFFFH

40 EEPROM

information check
type

3H Reference

only

For adjustment by the manufacture

41 Hardware

information check
type

E0H Reference

only

For adjustment by the manufacture

42 Hardware test type

7H

Reference

only

For adjustment by the manufacture

43 Special

monitor

type

0H 0H

~

FFFFFFFFH

Change

prohibited

44 (For

extension)

0