IAI America XSEL-KET User Manual

Page 181

Advertising
background image

162

Part 4 Commands

INTELLIGENT ACTUATOR



DIS (Set division distance at spline movement)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional DIS

Distance

Prohibited CP

[Function] Set a division distance for the interpolation implemented by a PSPL (move along spline)

command.
When a PSPL command is executed, a passing point will be calculated at each distance set
here and the calculated passing points will be used as interpolation points.
If the distance is set to “0,” an appropriate division distance will be calculated automatically so
that the actuator will operate at the set speed
The distance is input in mm.


















(Note)

If a PSPL command is executed without setting a distance with a DIS command, the default
value registered in “All-axis parameter No. 31, Default division distance” will be used.


[Example]

DIS

10

Set the division distance to 10 mm.

VEL

100

Set the speed to 100 mm/sec.

PSPL

100

120

Move continuously from position Nos. 100 to 120 along a
spline interpolation curve.

Interpolation points

Division distance