2. pnp specification, Caution – IAI America XSEL-KET User Manual

Page 41

Advertising
background image

22

Part 1 Installation

INTELLIGENT ACTUATOR



2-2. PNP

Specification

(1) Input

part

External Input Specifications (PNP Specification)

Item

Specification

Input voltage

24 VDC

10%

Input current

7 mA per circuit

ON/OFF voltage

ON voltage --- 8 VDC max.
OFF voltage --- 19 VDC min.

Insulation method

Photocoupler insulation

External devices

(1) No-voltage contact (minimum load of approx. 5 VDC/1 mA)
(2) Photoelectric/proximity sensor (PNP type)
(3) Sequencer transistor output (open-collector type)
(4) Sequencer contact output (minimum load of approx. 5 VDC/1 mA)


[Input circuit]
















* N: I/O24V power connector, 0V


Caution

If a non-contact circuit is connected externally, malfunction may result from leakage
current. Use a circuit in which leakage current in a switch-off state does not exceed 1
mA.


X-SEL controller’s input signal





At the default settings, the system recognizes the ON/OFF durations of input signals if they
are approx. 4 msec or longer. The ON/OFF duration settings can also be changed using I/O
parameter No. 20 (input filtering frequency).

Internal circuit

Input terminal

External power
supply 24 VDC

10%

N*

560

3.3 K

ON duration

OFF duration

+

-

Advertising