2. pnp specification, Caution – IAI America XSEL-KET User Manual
Page 41

22
Part 1 Installation
INTELLIGENT ACTUATOR
2-2. PNP
Specification
(1) Input
part
External Input Specifications (PNP Specification)
Item
Specification
Input voltage
24 VDC
10%
Input current
7 mA per circuit
ON/OFF voltage
ON voltage --- 8 VDC max.
OFF voltage --- 19 VDC min.
Insulation method
Photocoupler insulation
External devices
(1) No-voltage contact (minimum load of approx. 5 VDC/1 mA)
(2) Photoelectric/proximity sensor (PNP type)
(3) Sequencer transistor output (open-collector type)
(4) Sequencer contact output (minimum load of approx. 5 VDC/1 mA)
[Input circuit]
* N: I/O24V power connector, 0V
Caution
If a non-contact circuit is connected externally, malfunction may result from leakage
current. Use a circuit in which leakage current in a switch-off state does not exceed 1
mA.
X-SEL controller’s input signal
At the default settings, the system recognizes the ON/OFF durations of input signals if they
are approx. 4 msec or longer. The ON/OFF duration settings can also be changed using I/O
parameter No. 20 (input filtering frequency).
Internal circuit
Input terminal
External power
supply 24 VDC
10%
N*
560
3.3 K
ON duration
OFF duration
+
-