19 string operation – IAI America XSEL-KET User Manual

Page 228

Advertising
background image

209

Part 4 Commands

INTELLIGENT ACTUATOR



1-19 String Operation

SCPY (Copy character string)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

SCPY

Column

number

Column

number,

character literal

CC

[Function] Copy the character string in the column specified in operand 2 to the column specified in

operand 1.
Copy will be performed for the length set by a SLEN command.
If a character literal is specified in operand 2, copy will be performed for the entire length of
the literal.


[Example] SCPY

1

‘ABC’ Copy ‘ABC’ to column 1.

SLEN

10

Set the copying length to 10 bytes.

SCPY

100

200

Copy 10 bytes from column 200 to column 100

Advertising
This manual is related to the following products: