IAI America XSEL-KET User Manual

Page 416

Advertising
background image

Appendi

x

INTELLI

GENT A

CTUAT

OR

397


(In the panel window, the three digits after “E” indicate an error number.)C

Error No.

Error name

Description, action, etc.

D59

Fieldbus error (DPRAM write/read)

A DPRAM write/read error was detected.

D5A

Fieldbus error (TOGGLE timeout)

A TOGGLE timeout was detected.

D5B

Fieldbus error (Access-privilege retry over)

An access-privilege retry over error was detected.

D5C

Fieldbus error (Access-privilege open error)

An access-privilege open error was detected.

D5D

Fieldbus error (FBRS link error)

A FBRS link error was detected.

D5E

Fieldbus error (Mailbox response)

A mailbox response error was detected.

D60

Expanded-SIO 2/4 CH insulation power error

An Expanded-SIO insulation power error was detected.

D61

Expanded-SIO 1/3 CH insulation power error

An Expanded-SIO insulation power error was detected.

D62

Expanded-SIO baud-rate-generator clock oscillation error

An Expanded-SIO clock oscillation error was detected.

D63

Expanded-SIO UART paging error

An Expanded-SIO paging error was detected.

D64

Expanded-SIO assignment error

The “board channel assignment number” or “expanded-I/O slot assignment
number” in I/O parameter Nos. 100, 102, 104, 106, 108 or 110 may be outside
the input range or duplicated, a serial communication expansion board may not
be installed in the specified slot, or a “communication mode” other than RS232C
may have been selected when the “board channel assignment number” is other
than “1” or “2,” among other reasons.

D67 Motor/encoder

configuration

information

mismatch error

Driver parameter No. 25, “Motor/encoder configuration information” (motor
identification number, encoder identification number) does not match encoder
parameter No. 11, “Motor/encoder configuration information” (motor
identification number, encoder identification number). Check the parameter
values, encoder cable connection, etc.

D68

No remote-mode control support board error

Hardware supporting remote-mode control is not installed, although remote-
mode control (AUTO/MANU) is specified in I/O parameter No. 79.

D69

External terminal block overcurrent or power-supply error

Overcurrent or power-supply error in the external terminal block

D6A

Hardware unsupported function error

An attempt was made to use a function not supported by the hardware.

D6B

Overrun error

The overrun sensor was actuated.

D6C

Actual-position soft limit over error

The actual position exceeded a soft limit by the “soft limit/actual position margin”
or more.

D6D

Logic error

A logic error generated.

D6E

Motor drive-source OFF error (MPONSTR-OFF)

An OFF state of the power source (MPONSTR-OFF) was detected when the
system was not yet shut down (SHDWNSTR-OFF).

D6F

Optional password error

The optional function you want to use requires an optional password. Check
other parameter Nos. 30 to 32, etc., depending on the applicable function.

D7D

Option use permission error

Among others, check if any option is specified in a system program where use
of the option is not permitted.

E01

DMA address error

DMA transfer error