Part 3 Controller Data Structure

INTELLIGENT ACTUATOR


[1] Drive-source cutoff reset after control power ON























































Power ON

Control power (AC)

External input for
drive-source cutoff
(Emergency stop
switch, etc.)

The emergency stop switch is not ON.

System I/O
RDY OUT

Drive-source
cutoff/reset

Servo ON command

Be sure to reset within 200 ms.

Provide at least 1 sec.

[2] Emergency stop switch/safety gate/deadman switch input and drive-source cutoff/reset

Control power (AC)

External input for
drive-source cutoff
(Emergency stop
switch, etc.)

System I/O
RDY OUT

Drive-source
cutoff/reset

Servo ON command

Cut off

Reset

If the drive source is cut off and the cutoff is
reset repeatedly, provide an interval of at
least 5 sec.

The RDY OUT contacts
do not open even when
the drive source is cut off.

Within 200 ms

Be sure to reset within 200 ms.

Provide at least 1 sec.