IAI America XSEL-KET User Manual

Page 84

Advertising
background image

65

INTELLIGENT ACTUATOR

Part 2 Operation



(2) Timing

chart












































T1: Duration after the ready output turns ON

until input of external start signal is permitted
T1 = 10 msec min.


T2: Duration after the program number is input

until input of external start signal is permitted
T2 = 50 msec min


T3: Input duration of external start signal

T3 = 100 msec min.

[1] Program start

Ready output

Program 1

Program 2

Program number
input

External start input

Ready output

Input of input
function 003

Auto program start

Ready output

Input of input
function 001

Program starting

Ready output

Input of input
function 002

Servo ON

T1:

Time after the ready output turns ON
until input function 003 can be input

T1 = 10 msec min.

* Auto program start:

Set the number of the program you wish to
start automatically in other parameter No. 1,
“Auto-start program number.”

T1:

Time after the ready output turns ON
until input function 001 can be input

T1 = 10 msec min.


T2:

Time until the soft reset signal starts
functioning
T2 = 1 sec min.


T3:

Time after the soft reset signal is reset
until the ready signal is output

T1:

Time after the ready output turns ON
until input function 002 can be input

T1 = 10 msec min.


T2:

Interval after the servo is turned OFF
until it is turned ON again

T2 = 1.5 sec min.

[2] Auto program start

* When I/O parameter No. 33 is set to 2

[3] Soft reset signal

* When I/O parameter No. 31 is set to 1

[4] Servo ON signal

* When I/O parameter No. 32 is set to 1

T1

T3

T2

T1

T1

T2

T3

T1

T2

Advertising