6. The [Abs. Encoder Reset] dialog box will be displayed.




7. For Axis No., select the number of the

axis for which you have just replaced
the battery.
Note) Do not click the [Encoder

Rotation Data Reset 1]
button.
















8. Click the [Reset Encoder Error] button.


9. Close the dialog box.


Abs. Encoder Reset


10. From the [Controller (C)] menu on the PC software screen, select [Software Reset (R)], and restart

the controller.









Confirmation




This completes the reset procedure following a battery-voltage low warning.