402

(In the panel window, the three digits after “E” indicate an error number.)C

Error No.

Error name

Description, action, etc.

E79 Abnormal

response error when sending EEPROM-data setting

slave command

An abnormal response was received when an EEPROM-data setting
slave command was sent.

E7A

Maximum receive size over error when sending EEPROM-
data setting slave command

The receive size exceeded the limit value when an EEPROM-data
setting slave command was sent.

E7B

Motor-drive power ON timeout error

Abnormal current flow from the motor-drive power source

E7C

Register read/write test error

Error reading/writing the register

E7D

Linear-movement axis parameter error

Check axis-specific parameter Nos. 38, 68, 1, etc.

E7E

Parameter error

The parameter is invalid.

E7F

Stroke parameter error

Check axis-specific parameter Nos. 7, 8, 1, etc.

E80

Unsupported card error

An unsupported card is installed in an I/O slot.

E81

Priority auto-assignment card non-detection error

Priority auto-assignment card cannot be detected.

E82

Card mismatch error

The combination or positioning of I/O slot cards has a problem.

E83

I/O slot card error

The I/O slot card is invalid.

E84

Resolution parameter error

Check axis-specific parameter Nos. 47, 50, 51, 44, 42, 43, 1, 37, etc.

E85

Driver ready OFF factor indeterminable error

Driver ready OFF factor cannot be determined.

E86

Fieldbus error (FBVCCER)

A fieldbus error (FBVCCER) was detected.

E87

Fieldbus error (FBPOWER)

A fieldbus error (FBPOWER) was detected.

E88

Power error (Other)

A power error (Other) was detected. This error also generates when the
power OFF

 ON interval is short. After the power has been turned off,

be sure to wait for at least 5 seconds before turning it back on.
Abnormal regenerative resistance temperature is also suspected.

E89

SCIF open error in non-AUTO mode (Servo in use)

In a mode other than AUTO, opening of the serial 1 channel (also used
by the PC software/TP port) from a SEL program is prohibited while the
servo is in use (to ensure safety).

E8A

SEL program flash-ROM status error

Data is not written to the flash ROM correctly or written in an old,
incompatible application version.

E8B

Symbol definition table flash-ROM status error

Data is not written to the flash ROM correctly or written in an old,
incompatible application version.

E8C

Point data flash-ROM status error

Data is not written to the flash ROM correctly or written in an old,
incompatible application version.

E8D

Parameter flash-ROM status error

Data is not written to the flash ROM correctly or written in an old,
incompatible application version.

FF0 ~

F00

Shutdown error (hi_sysdwn () definition)

A shutdown error (hi_sysdwn () definition) was detected.

F03 ~

F58

Shutdown error (OS call error)

A shutdown error (OS call error) was detected.