IAI America XSEL-KET User Manual

Page 412

Advertising
background image

Appendi

x

INTELLI

GENT A

CTUAT

OR

393


(In the panel window, the three digits after “E” indicate an error number.)

Error No.

Error name

Description, action, etc.

C95

AUTO program number error

The setting of “Other parameter No. 1, Auto-start program number” is invalid.

C96

Start error from operation-abort program

Programs cannot be started from the “I/O processing program at
operation/program abort.” (Applicable only to main application version 0.33 or
earlier.)

C97

Program number error for I/O processing program at
operation/program abort

The setting of “Other parameter No. 2, I/O processing program number at
operation/program abort” is invalid.

C98

Program number error for I/O processing program at operation pause The setting of “Other parameter No. 3, I/O processing program number at all

operation pause” is invalid.

C99

Home sensor non-detection error

The home sensor cannot be detected. Check the wiring and sensor.

C9A

Creep sensor non-detection error

The creep sensor cannot be detected. Check the wiring and sensor.

C9B

Phase Z non-detection error

Phase Z cannot be detected. Check the wiring and encoder.

C9C

Defective phase-Z position error

The phase-Z position is defective. Normal wear and tear of the mechanical ends
and home sensor may also be a reason. Readjustment is necessary.

C9D

Card parameter write error

Error writing card parameters

C9E

Servo calculation overflow error

Internal servo calculation error

CA1

Abnormal absolute-data backup battery voltage (Driver analysis)

Check the connection of the absolute-data backup battery/replace the battery
and/or check the encoder cable connection, and then perform an absolute reset.

CA2

Abnormal absolute-data backup battery voltage (Main analysis)

Check the connection of the absolute-data backup battery/replace the battery
and/or check the encoder cable connection, and then perform an absolute reset.

CA3

Slave setting data out-of-range error

The data set to the slave is outside the allowable range.

CA4

Slave error response

An error response was returned from the slave.

CA5

Stop deviation overflow error

Movement may have occurred during stopping due to external force or operation
may have been restricted during deceleration. This error may also generate
when jog operation is restricted (due to contact with an obstacle, contact with a
mechanical end before home return, etc.) or when wiring error, faulty encoder or
faulty motor is detected during deceleration.

CA6

Palletizing number error

The specified palletizing number is invalid.

CA7

Setting error of even-numbered row count for palletizing zigzag

The set even-numbered row count for palletizing zigzag is invalid.

CA8

Setting error of palletizing pitches

The set palletizing pitches are abnormal.

CA9

Setting error of placement points in palletizing-axis directions

The set X/Y-axis direction counts for palletizing are invalid.

CAA

Palletizing PASE/PAPS non-declaration error

Neither PASE nor PAPS palletizing-setting command is set. Set either command.

CAB

Palletizing position number error

The specified palletizing position number is invalid.

CAC

Palletizing position number setting over

The specified palletizing position number exceeds the position number range
calculated for the current palletizing setting.

CAD

Palletizing PX/PY/PZ-axis duplication error

Any two of the specified PX, PY and PZ-axes for palletizing are the same axis.

CAE

Insufficient valid axes for palletizing 3-point teaching data

There are not enough valid axes in the point data for palletizing 3-point teaching.