IAI America XSEL-KET User Manual

Page 233

Advertising
background image

214

Part 4 Commands

INTELLIGENT ACTUATOR



STRH (Convert character string; hexadecimal)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional

STRH

Column

number

Data CC

[Function] Copy to the column specified in operand 1 a hexadecimal character string converted from the

data specified in operand 2.
Only the integer part will be adjusted to the length set by a SLEN command.
If the data exceeds the specified length, it will be cut off at the length set by a SLEN
command.
If the entire data has been converted within the length set by a SLEN command, the output
will turn ON.

(Note)

If the data specified in operand 2 is a negative value, eight columns will be required to covert
the entire data.


[Example]

SLEN

5

Set a format consisting of five integer digits.

STRH

1

255

The following values will be set in columns 1 to 5:

1

2

3

4

5

E F

LET

1

10

Assign 10 to variable 1.

LET

102

987.6543 Assign 987.6543 to variable 102.

SLEN

2.3

Set a length consisting of two integer digits and three
decimal digits.

STRH

*1

*102

The following values will be set in columns 10 and 11:

10 11

D B


“.3” in the SLEN command and “.6543” in variable 102,
which are the decimal part, will be ignored.
The integer part is expressed as ‘3DB’ in hexadecimal.
Since the length is two digits, however, “3” in the third
digit will be cut off.

Advertising