IAI America XSEL-KET User Manual

Page 384

Advertising
background image

365

Appendix

INTELLIGENT ACTUATOR


Other Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

45 Special

start

condition setting

0 0H

~

FFFFFFFFH

Bits 0 to 3:

Enable start from PC/TP in AUTO
mode = Used exclusively by the
manufacturer (0: Do not enable, 1:
Enable) (Main application version
0.36 or later)

Bits 4 to 7:

PIO program start (Input port 000)

Single start selection (0: Normal, 1:
Single start)

* When single start is selected, the

next PIO program start (input port
000) will not be accepted as long
as a program with the same
program number as the one
started by the last PIO program
start (input port 000) is running.

(Main application version 0.52 or
later)

Bits 8 to 11: Permission of auto program start

when all-operation-cancellation
factor is present
(0: Do not permit, 1: Permit)
(Main application version 0.79 or
later)

Bits 12 to 15: Permission of ON edge of PIO

program start (input port 000) when
all-operation-cancellation factor is
present
(0: Do not permit, 1: Permit)
* This parameter specifies an ON
edge acceptance condition and if the
start condition is not satisfied, “Error
No. A1E, Start condition non-
satisfaction error” will generate.
(Main application version 0.79 or
later)