Part 4 Commands



PSIZ (Check position data size)

Command, declaration

Extension condition

(LD, A, O, AB, OB)

Input condition

(I/O, flag)

Command,
declaration

Operand 1

Operand 2

Output

(Output, flag)

Optional Optional PSIZ

Variable

number

Prohibited CP

[Function] Set an appropriate value in the variable specified in operand 1 in accordance with the

parameter setting.


 When “Other parameter No. 23, PSIZ function type” = 0

The maximum number of position data that can be stored in the controller will be set.
(Regardless of whether the data are used or not.)

 When “Other parameter No. 23, PSIZ function type” = 1

The number of point data used will be set.


[Example] PSIZ 1

When “Other parameter No. 23, PSIZ function type” = 0
The maximum number of position data that can be stored in variable 1 will be set.

When “Other parameter No. 23, PSIZ function type” = 1

The number of point data currently used will be set in variable 1.