Appendi

x

INTELLI

GENT A

CTUAT

OR

379

Program run (Application only)

Error

level

System error

assignment

source

Error No.

(HEX)

Display (7-

segment

display, etc.)

Error list

(Application

only)

Error LED

output (MAIN

only)

Other parameter No. 4 = 0

Other parameter No. 4 = 1

Error reset

(Application

only)

Remarks

MAIN application

B00 ~ B9F

MAIN core

BA0 ~ BBF

PC

BC0 ~ BDF

TP

BE0 ~ BFF

MAIN application

C00 ~ CCF

MAIN core

CD0 ~ CDF

PC

CE0 ~ CEF

Oper

ation-cancellation level

TP CF0

~CFF

The program in which the error
generated will be cancelled.
(Except for axis errors, a
cancellation factor is present
only for the moment the error
occurs.)
* However, in the case of an
error requiring servo OFF or
all-axis servo OFF, all
programs other than the “I/O
processing program at
operation/program abort” will
be cancelled.

All programs other than the
“I/O processing program at
operation/program abort”
will be cancelled. (Except
for axis errors, a
cancellation factor is
present only for the
moment the error occurs.)

Enabled.

Errors affecting
operation. The
system will
attempt to reset
minor errors below
this level using an
auto-reset function
via external active
command
(SIO/PIO)
(application only).

MAIN application

MAIN core

-

PC
PC (Update tool)

TP
MAIN application

600 ~6CF

MAIN core

-

PC

6D0 ~ 6DF

PC (Update tool)

6E0 ~ 6EF

TP

6F0 ~ 6FF

MAIN application

D00 ~ D8F

MAIN core

D90 ~ DAF

PC

DB0 ~ DCF

PC (Update tool)

DD0 ~ DDF

TP

DE0 ~ DFF

MAIN application

E00 ~ E8F

MAIN core

E90 ~ EBF

PC

EC0 ~ EDF

Cold-

star

t level

TP

EE0 ~ EFF

(Core only)

The program in which the error
generated will be cancelled.
* However, in the case of an
error requiring drive-source
cutoff, servo OFF or all-axis
servo OFF (initialization error,
power error, etc.), all programs
other than the “I/O processing
program at operation/program
abort” will be cancelled.

All programs other than the
“I/O processing program at
operation/program abort”
will be cancelled

Not

enabled.

The controller
power must be
reconnected
(MAIN only).
(The CPU and OS
will run properly.)

MAIN application

MAIN core

-

PC
PC (Update tool)

TP
MAIN application

FF0 ~ FBF

MAIN core

FC0 ~ FCF

PC

FD0 ~ FDF

System-down level

TP

FE0 ~ FEF

All programs will be cancelled.

Not

enabled.

The controller
power must be
reconnected
(MAIN only).
(The CPU and OS
will not run.)

Note)

Secret-level errors are not actual errors. Internal statuses are registered in an error list as secret-level errors, when deemed necessary, in order to facilitate error analysis.