Part 1 Installation

INTELLIGENT ACTUATOR



















If multiple controllers are to be connected on top of one another, prevent the controller above from
taking in the exhaust air from the controller below.


3. Power Source

Provide a 230-VAC, single-phase power source.


4. Noise Measures and Grounding

(1) Wiring and power source

PE on the power terminal block is used for protective grounding. Provide Class D grounding from this

terminal.

Use a grounding cable with a wire size of 1.0 mm

2

(#AWG17) or more, which should not be smaller

than the AC power cable.

Install an AC line noise filter to prevent noise generating in the controller from traveling through the

power line to affect other devices.





















Install a noise filter (MXB-1210-33 by Densei-Lambda) near the power connector on the X-SEL controller
side.

Airflow direction

Fan

Airflow

150 mm min.

150 mm min.

150 mm

min.

230-VAC power source

C.POWER M.POWER

N

L

N

L

X-SEL controller

Class D grounding
(protective grounding)

Drive-

power

cutoff

control

circuit


Noise

filter

Accessory