(In the panel window, the three digits after “E” indicate an error number.)C

Error No.

Error name

Description, action, etc.

CAF

Excessive valid axes for palletizing 3-point teaching data

There are too many valid axes in the point data for palletizing 3-point teaching.
Axes to comprise the palletizing PX/PY planes cannot be specified.

CB0

Mismatched valid axes for palletizing 3-point teaching data

The valid axis pattern in the point data for palletizing 3-point teaching does not
match.

CB1

Offset setting error at palletizing 3-point teaching

Zigzag offset (not zero) cannot be set in palletizing 3-point teaching, if the
reference point is the same as the end point of the PX-axis.

CB2

BGPA/EDPA pair-end mismatch error

The BGPA/EDPA syntax is invalid. EDPA was declared before BGPA, or
another BGPA was declared after BGPA without first declaring EDPA.

CB4

Arch-motion Z-axis non-declaration error

Z-axis has not been declared by PCHZ or ACHZ.

CB5

BGPA non-declaration error during palletizing setting

Palletizing setting cannot be performed without first declaring BGPA. Declare
BGPA.

CB6

Palletizing point error

The palletizing points are invalid (no arch motion data other than the Z-axis
component, etc.).

CB7

Arch-trigger non-declaration error

Declare arch triggers using PTRG or ATRG.

CB8

No 3-point teaching setting error at palletizing angle acquisition

The palletizing angle cannot be acquired until setting by palletizing 3-point
teaching is complete.

CB9

PX/PY-axis indeterminable error at palletizing angle acquisition

Angle cannot be calculated because there are too many valid axes in the 3-point
teaching data and thus PX/PY-axes cannot be specified.

CBA Reference-axis/PY/PY-axis

mismatch error at palletizing angle

acquisition

Angle cannot be calculated because the reference axis for angle calculation is
neither of the axes comprising the PX/PY-axes as set by 3-point teaching.

CBB Reference-point/PX-axis

end-point duplication error at palletizing

angle acquisition

Angle cannot be calculated because the reference point of 3-point teaching is
the same as the PX-axis end-point data other than the PZ-axis component and
thus arc tangent cannot be calculated.

CBC

Palletizing motion calculation error

Trapezoid control calculation error for palletizing motion

CBD

MOD command divisor 0 error

“0” was specified as the divisor in the MOD command.

CBE

Target-locus boundary over error

The target position or movement locus exceeded the positioning boundary in the
infinite-stroke mode.

CBF

Positioning distance overflow error

The positioning distance is too large.
If the system is of the absolute encoder specification and it has just been
relocated or when “Error No. C74, Actual-position soft limit over error” has also
generated, the absolute reset may not have been executed correctly and
consequently the servo packet calculation counter may have overflowed due to
a current position error. Perform an absolute reset again according to the
procedure specified in the operation manual.
(The current position cannot be recognized correctly only by clicking “Reset
Encoder Error” on the absolute reset screen. Be sure to perform an absolute
reset by strictly following the specified procedure.)

CC0

Axis mode error

The axis mode is invalid.

CC1

Speed change condition error

An attempt was made to change the speed of an axis whose speed cannot be
changed (axis operating in S-motion, etc.).

CC2

Driver parameter list number error

The driver parameter list number is invalid.

CC3

Angle error

The angle is invalid.