(In the panel window, the three digits after “E” indicate an error number.)

Error No.

Error name

Description, action, etc.

A44 Point-data

count

specification error

The specified number of point data is invalid.

A45

Symbol-record count specification error

The specified number of symbol records is invalid.

A46

Variable-data count specification error

The specified number of variable data is invalid.

A48

Error-detail query type 1 error

Error-detail query type 1 is invalid.

A49

Error-detail query type 2 error

Error-detail query type 2 is invalid.

A4A

Monitoring data type error

The data type for monitoring data query is invalid.

A4B

Monitoring-record count specification error

The specified number of records for monitoring data query is invalid.

A4C

Monitoring-operation special command register busy error

The driver special command ACK generated a timeout during
monitoring operation.

A4E

Parameter register busy error at issuance of slave command

The driver special command ACK generated a timeout at issuance of a
slave command.

A4F

Software reset refusal error during operation

Software reset (SIO) is prohibited during operation (program is running,
servo is in use, etc.).

A50

Drive-source recovery request refusal error

The drive-source cutoff factor (error, deadman switch, safety gate,
emergency stop, etc.) has not been removed.

A51

Operation-pause reset request refusal error

The all-operation-pause factor (drive-source cutoff, operation-pause
signal, deadman switch, safety gate, emergency stop, etc.) has not
been removed.

A53

Refusal error due to servo ON

A processing not permitted during servo ON was attempted.

A54

Refusal error due to unsupported function

The function is not supported.

A55

Refusal error due to exclusive manufacturer function

A processing not opened to users other than the manufacturer was
attempted.

A56

Refusal error due to invalid data

The data is invalid.

A57

Program start duplication error

An attempt was made to start a program currently running.

A58

BCD error warning

The BCD value being read may be invalid, or the value being written
(variable 99) may be a negative value, among other reasons.

A59

IN/OUT command port flag error warning

The number of I/O ports (flags) may have exceeded 32, among other
reasons. Check the I/O port (flag) specifications.

A5B

Character-string

 value conversion error warning

The specified number of converting characters is invalid or characters
that cannot be converted to value are included.

A5C

Copying-character count error warning with SCPY command

The specified number of copying characters is invalid.

A5D

SCIF open error in non-AUTO mode

The channel was opened in a non-AUTO mode. In the MANU mode, the
PC/TP connection must be forcibly disconnected before opening the
serial channel opened to the user. Exercise caution.

A5E

I/O-port/flag count specification error

The specified number of I/O ports/flags is invalid.

A5F

Fieldbus error (LERROR-ON)

A LERROR-ON was detected.

A60

Fieldbus error (LERROR-BLINK)

A LERROR-BLINK was detected.