8

Part 1 Installation

INTELLIGENT ACTUATOR



b. DC solenoid valve, magnet switch, relay

Measure --- Install a diode in parallel with the coil. Determine the diode capacity in accordance with

the load capacity.


In a DC circuit, connecting a diode in reversed polarity will
damage the diode, internal parts of the controller and DC
power supply. Exercise due caution.













The above noise elimination measures are particularly important when a 24-VDC relay is driven
directly by a controller output and there is also a 100-VAC solenoid valve, etc.



Reference Circuit Diagram




























Diode

Controller

Surge absorber

Solenoid valve

OUT

COM

CR

+24 V

0 V

100 VAC

CR

0 V

SOL